Dimensional Specs & Data for
Rigid-Plastic
Grease & Oil Interceptors
|
Standard HDPE or PP Grease & Oil Interceptor Dimensions & Fitting Data |
|
Grease Trap Model #
|
Oil Trap Model #
|
GPM Flow Rate
|
Grease Capacity, Lbs.
|
Approx. Outside Dimen. LxWxH In.
|
Minimum Wall Thickness, In.
|
Approx. Weight, Lbs.
|
Standard Inlet, Outlet & C.O. Plug Sizes, In.
|
Optional Vent Connection Size, In.
|
Standard Fitting Connections, In.
|
Approx. Typical Fitting Centerlines Height in In. |
|
Inlet |
Outlet |
Optional Vent |
|
GI-4 |
OI-4 |
4 |
8 |
26x13x12 |
3/16 |
35 |
2 |
2 |
IPS Threads |
8 1/2 |
8 1/2 |
9 1/2 |
|
GI-7 |
OI-7 |
7 |
14 |
25x15x13 |
3/16 |
35 |
2 |
2 |
IPS Threads |
9 1/2 |
9 1/2 |
10 1/2 |
|
GI-10 |
OI-10 |
10 |
20 |
27x15x13 |
3/16 |
45 |
2 |
2 |
IPS Threads |
9 1/2 |
9 1/2 |
10 1/2 |
|
GI-15 |
OI-15 |
15 |
30 |
27x18x20 |
3/16 |
45 |
2 |
2 |
IPS Threads |
13 |
13 |
14 |
|
GI-20 |
OI-20 |
20 |
40 |
30x15x19 |
3/16 |
50 |
3 |
3 |
IPS Threads |
16 |
16 |
17 |
|
GI-25 |
OI-25 |
25 |
50 |
33x16x24 |
3/16 |
60 |
3 |
3 |
IPS Threads |
20 |
20 |
22 |
|
GI-35 |
OI-35 |
35 |
70 |
38x20x25 |
3/16 |
75 |
3 |
3 |
IPS Threads |
20 |
20 |
22 |
|
GI-50 |
OI-50 |
50 |
100 |
44x22x25 |
1/4 |
85 |
3 |
3 |
IPS Threads |
20 |
20 |
22 |
|
Low Profile Types |
|
GIL-20 |
OIL-20 |
20 |
40 |
45x23x14 |
3/16 |
40 |
3 |
3 |
IPS Threads |
9 |
9 |
10 |
|
GIL-35 |
OIL-35 |
35 |
70 |
51x28x13 |
1/4 |
55 |
3 |
3 |
IPS Threads |
8 |
8 |
9 |
|
GIL-50 |
OIL-50 |
50 |
100 |
51x29x19 |
1/4 |
65 |
3 |
3 |
IPS Threads |
13 |
13 |
13 |
|
NOTE: Larger Units and Special Sizes Available
*Denoted 4" Connections Also Available
** Outside Length Includes Fittings |
***Two 2" Vent Connections and One 1 1/2" Oil Draw-Off Connection Are Standard On All Oil Interceptors.
Extensions Available to Increase Height of Units, for Below Ground Installations |
Figures may vary slightly in above table. special sizes (Dimensions) available, at added cost. Fitting centerlines may be changed upon request, at no extra cost. For below grade or floor installation, fitting centerlines should be given FROM TOP OF COVER DOWN TI FITTING CENTER. Interceptors include appropriate flow restrictor fitting, heavy-duty cover with recessed bolt holes, standard inlet and outlet fittings, baffles, cleanout, Neoprene gasketing and stainless steel nuts, bolts and washers. Add for vent connections, if desired. Single bolt securing of covers, available upon request; Extensions available, for added cost. Lower inlets available, upon request, at no extra cost. Larger and special sizes are available. NOTE: Centerlines are from bottom of traps to center of fitting, as shown above, unless other wise requested.
NOTE: Prices for Traps include same size flow control (restrictor) Tee Fitting, as Inlet and Outlet Size.
Previous Page | Next Page